← All experiments
research

School work-order routing

A synthetic language challenge: simple substring rules versus live Jev, with every ticket available for inspection.

Read the experiment ↓
Format
Research & findings
Reading time
8 minutes
Level
intermediate

Before the first bell

Illustrative film with music. The written study below contains the findings and limitations.

Download the approved film (MP4, 13 MB)

Can a router read past the keyword?

An empty old-light-bulb bin sits beside recycling that needs collecting. The job is custodial; a light-related keyword can send it to electrical. We compared simple substring rules with live Jev classification on synthetic work orders. This study measures routing decisions against authored labels. It does not measure staff time saved, repairs completed, school safety, or dispatch outcomes.

Results: development and challenge set

Correct route, including the human-review route
BatchSubstring rulesLive Jev
Development (32)31/3232/32
Challenge holdout (24)9/24 (37.5%)23/24 (95.83%)
Trade cases in holdout (18)5/1817/18
Review-required cases (6)4/66/6

The development batch was written alongside the rules. Its near-perfect scores are development evidence. The primary 24-case holdout was authored by a separate agent after the implementation and prompt were frozen. That writer had seen the rules. These are deliberately challenging language examples, including synonyms and irrelevant trade mentions, rather than a representative school inbox or a blind field evaluation. The agents share model lineage.

Method and policy

Six trade routes—plumbing, electrical, HVAC, carpentry, custodial and grounds—plus human review. Safety hazards, ambiguity and insufficient detail require review before trade assignment; negated hazards do not. The baseline lowercases text, checks a short list of hazard and uncertainty phrases, then returns the first matching trade substring. It has no learned semantics or word-boundary matching. A stronger rules baseline may do better.

Jev used the live jev-1.13.0 model through MCP. Each response was checked for served model and a complete valid probability distribution. Calls were sequential in fixed ticket order, five-second timeout, no retries. Rules ran first, Jev second; there was no counterbalancing or repeated trial. Labels were loaded after both inference arms finished. No rules or thresholds were tuned after holdout results.

Accuracy came with added latency

For all 24 tickets, rules took under 1 ms and Jev took 3.86 seconds. The recorded wall times were 0.0005215 and 3.856334083 seconds respectively. Rules timing is an in-process CPU microbenchmark that excludes inbox ingestion, startup, dispatch and human review. Jev wall time includes MCP launch, credential lookup, tool discovery, sequential calls and shutdown. Neither arm had an error or timeout. These timings are different execution envelopes and do not establish operational throughput or a speed advantage. No human handling time was measured.

Two tickets worth reading

H10

The waste bin marked “old light bulbs” is empty. The ordinary recycling beside it is overflowing and needs collecting.

The old-light-bulb bin was empty; the recycling nearby needed collection. Rules chose electrical. Jev correctly chose custodial.

H17

The lock is fixed. Would someone sweep up the sawdust left on the office floor?

After a lock repair, sawdust needed sweeping. Rules chose carpentry. Jev deferred to review; the authored label was custodial. This unnecessary referral was Jev’s sole disagreement.

Across the holdout, rules directly assigned five wrong tickets, including two that required review. Jev made zero wrong direct assignments and one unnecessary referral. Rules deferred 14 tickets to review; Jev deferred seven. These counts describe this challenge set and do not establish safety in operation.

Inspect every decision

The download includes all 24 synthetic tickets, authored labels, both choices, correctness, per-call timing, Jev distributions, served model, usage and request hashes.

Read all 24 ticket decisions

H01

We're out of paper towels in both dispensers outside the music room.

Expected: custodial · Rules: review · Jev: custodial

H02

The row of lamps above the whiteboard stays dark even after I change the bulbs.

Expected: electrical · Rules: review · Jev: electrical

H03

The metal cover on the socket is warm and smells scorched.

Expected: review · Rules: review · Jev: review

H04

Could someone prune the branches hanging over the outdoor reading benches?

Expected: grounds · Rules: carpentry · Jev: grounds

H05

The radiator in 2B stays stone cold even when the rest of the building warms up.

Expected: hvac · Rules: review · Jev: hvac

H06

The latch on the supply closet no longer catches.

Expected: carpentry · Rules: review · Jev: carpentry

H07

The staff washbasin empties so slowly there's still a bowlful after lunch.

Expected: plumbing · Rules: review · Jev: plumbing

H08

We keep hearing a thump above the ceiling tiles. We haven't located it.

Expected: review · Rules: review · Jev: review

H09

The socket behind the projector cart is dead. We've tested the cart elsewhere.

Expected: electrical · Rules: review · Jev: electrical

H10

The waste bin marked “old light bulbs” is empty. The ordinary recycling beside it is overflowing and needs collecting.

Expected: custodial · Rules: electrical · Jev: custodial

H11

The door to the kiln room shuts fine. Its wooden sill has split and needs replacing.

Expected: carpentry · Rules: carpentry · Jev: carpentry

H12

Yesterday's leak has stopped, but there's moisture inside the outlet plate.

Expected: review · Rules: electrical · Jev: review

H13

The hedge beside the kindergarten courtyard is growing through the fence.

Expected: grounds · Rules: review · Jev: grounds

H14

The handle on the kitchenette faucet spins freely and the flow won't shut off.

Expected: plumbing · Rules: review · Jev: plumbing

H15

The air from the heating vent comes out chilly all morning despite the setting.

Expected: hvac · Rules: hvac · Jev: hvac

H16

Report says “it's broken again” with a room number and no description.

Expected: review · Rules: review · Jev: review

H17

The lock is fixed. Would someone sweep up the sawdust left on the office floor?

Expected: custodial · Rules: carpentry · Jev: review

H18

The cafeteria pendant lamps never come on, even with fresh bulbs.

Expected: electrical · Rules: review · Jev: electrical

H19

A loose wooden bookcase bracket needs securing in the reading corner.

Expected: carpentry · Rules: review · Jev: carpentry

H20

Please rake the fallen leaves off the athletics path before practice.

Expected: grounds · Rules: grounds · Jev: grounds

H21

The emergency exit bar moves, but nobody can get the door open from the hall.

Expected: review · Rules: carpentry · Jev: review

H22

The bottle filler above the drinking fountain gives a thin trickle.

Expected: plumbing · Rules: plumbing · Jev: plumbing

H23

The puddle under the air handler could be condensation or a cracked supply line. Which crew should look?

Expected: review · Rules: review · Jev: review

H24

The thermostat display works, but the radiators in the entire east wing stay cold.

Expected: hvac · Rules: hvac · Jev: hvac

What this supports—and what comes next

Live Jev handled this synthetic language challenge more accurately than these simple substring rules, while adding latency. Twenty-four selected cases, one run, a weak baseline and synthetic labels cannot establish general superiority, production safety, cost, capacity or ROI. The optional OpenAI Decisions comparison was not run because an authorized API key was unavailable.

Before deployment, facilities operators should adjudicate disagreements, test a representative consented inbox sample, compare a stronger production baseline, repeat and randomize trials, and measure the full review and dispatch workflow. No real tickets were dispatched and no staff outcomes were observed.

All experiments →